Accuracy of Lumbosacral Pedicle Screw Placement in Dogs: A Novel 3D Printed Patient-Specific Drill Guide versus Freehand Technique in Novice and Expert Surgeons

Authors
Jos J Bongers, Nathan Wilkinson, Manabu Kurihara, Janis P Bridges, Wendy Baltzer, Andrew J Worth
Journal
Vet Comp Orthop Traumatol. 2022 Nov;35(6):381-389. doi: 10.1055/s-0042-1750433.

Objective: The aim of this study was to compare the accuracy of pedicle screw placement at the canine lumbosacral junction using a novel unilateral three-dimensional printed patient-specific guide (3D-PSG) versus a freehand drilling technique. Additionally, accuracy of screw placement between a novice and an experienced surgeon was determined.

Study design: Preoperative computed tomography images from 20 lumbosacral cadaveric specimens were used to design a novel unilateral 3D-PSG for the L7 and sacral vertebrae which was printed in acryl-nitrile butadiene styrene plastic. A novice and an expert surgeon each placed 3.5mm cortical screws in 10 cadavers; on the left using the unilateral 3D-PSG and by the freehand (anatomic landmark) technique on the right.

Results: Sixty screws were placed using the unilateral 3D-PSG and 60 using the freehand technique. There was no statistical difference in accuracy for the comparison between methods performed by the expert (p = 0.679) and novice (p = 0.761) surgeon, nor between an expert and novice surgeon overall (p = 0.923). Unexpectedly, the use of a unilateral 3D-PSG increased variability for the expert surgeon in our study (p = 0.0314).

Conclusion: Using a novel unilateral 3D-PSG did not improve the accuracy of screw placement for lumbosacral stabilization by a novice surgeon compared with an expert surgeon in lumbar spine surgery. This may reflect a suboptimal PSG design.